Posts

Showing posts from September, 2021

Storage of goods and warehousing in India

Image
  https://maxcelgloballogistics.wordpress.com/2021/09/21/storage-of-goods-and-warehousing-in-india/ https://dribbble.com/shots/16493952-Storage-of-goods-and-warehousing-in-India https://issuu.com/maxcelgloballogistics/docs/storage_of_goods_and_warehousing_in_india.docx https://www.everforo.com/g/maxcelgloballogistics/thread/storage-of-goods-and-warehousing-in-india-10914 https://maxcelglobal.livejournal.com/692.html https://www.wattpad.com/story/285878488-storage-of-goods-and-warehousing-in-india https://www.dropbox.com/scl/fi/co5f34ueeuvzfumalasbc/Storage-of-goods-and-warehousing-in-India.docx?dl=0&rlkey=ts8pm36igpq10kkyvt4q0vpmv https://app.box.com/s/cyqfu21j5mnrqg1rzd7wftt5gjzwlfzz https://maxcelgloballogistics.doodlekit.com/blog/entry/17390643/storage-of-goods-and-warehousing-in-india https://diigo.com/0lw25p https://importantcomputertraveler

PRP method for discogenic issues

Image
  Discogenic pain is sourced from damaged vertebral disc which in turn is damaged due to degenerative disc disease. However it might be noted that not all degenerative discs cause pain. This disease occurs naturally with age mostly after the age 60. Non surgical methods such as pain medication and physiotherapy are employed to treat this pain. Chronic pain is severe and limits the patient’s ability to function, thus requiring surgery. Discography is employed to confirm pain that comes from a specific disc. Lumbosacral discogenic pain results in axial low back pain and arises from facet joints, spinal muscles and ligaments. The pain which occurs due to wear and tear in the spinal disc is characterized by weakness, numbness and shooting pains in the arms and legs. Severe herniated disc in the lower back and neck might cause paralysis. It may also begin from a trauma like car accident for instance. The spinal degeneration begins with deterioration and curvature which signifies misal

Significance of removing acidity in transformer oil

Image
  Monitoring transformer for its fitness is inevitable to acquire uninterrupted power supply. Maintaining the good working condition of transformer oil protects the equipment from tripping and other failures. The wellbeing of the transformer is obsolete, if its transformer oil is contaminated, lest the apparatus would bulge or burst in the worst cases. Regular testing of the oil ensures safety and uninterrupted power supply while it serves insulation and cooling of the transformer. Though all oils are good insulators, vegetable oils and animal fats are not used in transformers since the fatty acids attack fibrous elements used in winding insulation. When transformer oil comes in contact with atmospheric oxygen it goes through chemical reaction which results in sludge or acid formation and settles in windings of the transformer. The oil deterioration that occurs deprives the insulating liquid of its cooling attributes and leads to expensive repairs. Oxidation and contamination